PROGRAM PSYCHE VERSION 8.00 Run on 16-Nov-2008 Input File Specification------------------------Cu63ng.endf Check the Entire File TAPE BEING PROCESSED IS NUMBERED 32 LABEL IS IAEA-CRP Therapeutic Radionuclides Library ENDF-6 format CHECK MATERIAL 2925 (NO WARNINGS DETECTED IN SECTIONS WITHOUT COMMENTS) -------------------------------------------------------------------------------- FILE 1 SECTION 451 29-Cu- 63 IAEA-CRP EVAL-JUN07 Sublet, Kopecky, Forrest DIST-JUN07 ----IAEA-CRP/TR MATERIAL 2925 -----INCIDENT NEUTRON DATA ------ENDF-6 FORMAT -------------------------------------------------------------------------------- FILE 2 SECTION 151 ISOTOPE MASS = 63. HAS NO RESONANCES GIVEN. CHECK ON ISOTOPE PROPERTIES -------------------------------------------------------------------------------- FILE 3 SECTION 102 THERMAL CROSS SECTIONS AND RESONANCE INTEGRALS E = THERMAL SIGMA = 4.47341E+00 RESONANCE INTEGRAL, 0.5 EV CUTOFF IS 4.97670E+00 -------------------------------------------------------------------------------- FILE 8 SECTION 102 -------------------------------------------------------------------------------- FILE 33 SECTION 102