Gunst Nuclear Science and Engineering, 56:3 (1975) Table XIV Measured values of decay heat in the sample (uncorrected for gamma escape and actinide contributions) 232Th Sample 41 Cooling Decay Heat (W) Time (h) Meas Calc 14.42 35.8 37.9 18.38 35.4 36.2 41.23 30.7 31.5 41.80 31 31.5 65.07 29.15 29.76 66.40 28.84 29.69 185.6 24.71 25.29 186.0 24.79 25.27 353.7 20.57 20.89 354.2 20.7 20.87 499.9 17.56 17.79 501.1 17.59 17.76 547.5 16.58 16.89 549.0 16.29 16.86 665.6 14.42 14.86 668.4 14.51 14.82 762.5 13.47 13.39 762.6 13.29 13.39 1511 5.96 6.04 1511 6.21 6.04 2565 1.92 2.01 2899 1.36 1.43 3235 1.01 1.02 3571 0.74 0.73 4075 0.45 0.45 4385 0.31 0.34 4918 0.21 0.21