ENTRY 14793 20221004 150514793000 1 SUBENT 14793001 20221004 150514793001 1 BIB 10 19 14793001 2 TITLE Doppler Effect in the Slow Neutron Resonance of Rhodium14793001 3 AUTHOR (H.H.Landon) 14793001 4 REFERENCE (J,PR,93,931(Q4),1954) 14793001 5 #doi:10.1103/PhysRev.93.909 14793001 6 REL-REF (A,11932001,V.L.Sailor,J,PR,91,53,1953) Predicted cross14793001 7 section. 14793001 8 INSTITUTE (1USABNL) 14793001 9 FACILITY (SPECC,1USABNL) 14793001 10 METHOD (TRN) The variation in transmission of a rhodium foil 14793001 11 to 1.26-eV neutrons has been measured as a function 14793001 12 of foil temperature using the BNL crystal 14793001 13 spectrometer. A change in transmission of 14793001 14 approximately two percent per 100 degree temperature 14793001 15 change has been observed over a temperature range 14793001 16 from 120 degrees K to 860 degrees K. 14793001 17 ERR-ANALYS (DATA-ERR) No details on sources of uncertainties. 14793001 18 CORRECTION Correction for instrument resolution and Doppler 14793001 19 effect. 14793001 20 HISTORY (20221004C) BP 14793001 21 ENDBIB 19 0 14793001 22 NOCOMMON 0 0 14793001 23 ENDSUBENT 22 0 1479300199999 SUBENT 14793002 20221004 150514793002 1 BIB 2 3 14793002 2 REACTION (45-RH-103(N,TOT),,SIG,,RES) 14793002 3 STATUS (TABLE,,H.H.Landon,J,PR,93,931(Q4),1954) 14793002 4 page 931 of J,PR,93,931(Q4),1954. 14793002 5 ENDBIB 3 0 14793002 6 NOCOMMON 0 0 14793002 7 DATA 3 1 14793002 8 EN-RES DATA DATA-ERR 14793002 9 EV B B 14793002 10 1.26 4850.0 200.0 14793002 11 ENDDATA 3 0 14793002 12 ENDSUBENT 11 0 1479300299999 ENDENTRY 2 0 1479399999999