ENTRY 23782 20230202 231523782000 1 SUBENT 23782001 20230202 231523782001 1 BIB 15 48 23782001 2 TITLE Cross-section measurements of the 156Dy(n,2n)155Dy 23782001 3 reaction at neutron energies higher than 17 MeV 23782001 4 AUTHOR (E.Georgali, N.Patronis, A.Anastasiadis, X.Aslanoglou, 23782001 5 M.Axiotis, S.Chasapoglou, Z.Eleme, S.Harissopulos, 23782001 6 A.Kalamara, M.Kokkoris, A.Lagoyannis, E.Mitsi, 23782001 7 M.I.Savva, I.E.Stamatelatos, T.Vasilopoulou, 23782001 8 R.Vlastou) 23782001 9 INSTITUTE (2GRCIOA,2SWDUPP,2GRCATH,2GRCTUA) 23782001 10 (2SWDSWD) Swedish Radiation Safety Authority, Stockholm23782001 11 REFERENCE (J,PR/C,104,064603,2021) 23782001 12 #doi:10.1103/PhysRevC.104.064603 23782001 13 FACILITY (VDGT,2GRCATH) 23782001 14 INC-SOURCE (D-T) 23782001 15 SAMPLE The Dy foils with a diameter of 13 mm and thicknesses 23782001 16 of 0.9, 0.9, and 0.8 cm for each of the irradiations, 23782001 17 respectively. 23782001 18 METHOD (ACTIV) 23782001 19 (GSPEC) 23782001 20 (STTA) Each of Dy foils was placed between Al monitor 23782001 21 foils of equal diameter 23782001 22 DECAY-DATA (66-DY-155,9.9HR,DG,226.9,0.687) 23782001 23 DETECTOR (HPGE) 23782001 24 80% relative efficiency HPGe detector for the 23782001 25 measurement of the 155Dy activity 23782001 26 40% relative efficiency HPGe detector for the 23782001 27 measurement of the activity of the reference foils 23782001 28 MONITOR (13-AL-27(N,A)11-NA-24,,SIG) 23782001 29 MONIT-REF (,,3,IRDFF-1.05,,2014) 23782001 30 DECAY-MON (11-NA-24,14.997HR,DG,1368.626,0.999936) 23782001 31 ERR-ANALYS (ERR-T) The cross-section uncertainty was determined 23782001 32 by summing up quadratically the following individual 23782001 33 uncertainties. 23782001 34 (ERR-1) Neutron flux 7% 23782001 35 (ERR-2) 80% HPGe detector efficiency 3% 23782001 36 (ERR-3) 226.9-keV gamma-ray intensity per decay 2.3% 23782001 37 (ERR-4) 156Dy natural abundance 5.4% 23782001 38 (ERR-5) 40% HPGe detector efficiency 3.0% 23782001 39 (ERR-S) Statistical uncertainty of cross section 23782001 40 En (MeV) 226.9-keV counting peak statistics 23782001 41 17.1 8.2% 23782001 42 18.1 13.7% 23782001 43 19.0 16.4% 23782001 44 En(MeV) Reference foils peak count. stat. (front-back)23782001 45 17.1 3.1-3.1% 23782001 46 18.1 4.6-5.1% 23782001 47 19.0 4.1-5.1% 23782001 48 (ERR-SYS) Systematic uncertainty of cross section. 23782001 49 HISTORY (20230202C) VS 23782001 50 ENDBIB 48 0 23782001 51 COMMON 5 3 23782001 52 ERR-1 ERR-2 ERR-3 ERR-4 ERR-5 23782001 53 PER-CENT PER-CENT PER-CENT PER-CENT PER-CENT 23782001 54 7. 3. 2.3 5.4 3.0 23782001 55 ENDCOMMON 3 0 23782001 56 ENDSUBENT 55 0 2378200199999 SUBENT 23782002 20230202 231523782002 1 BIB 2 2 23782002 2 REACTION (66-DY-156(N,2N)66-DY-155,,SIG) 23782002 3 STATUS (TABLE) Table VI of Phys.Rev.C104(2021)064603 23782002 4 ENDBIB 2 0 23782002 5 NOCOMMON 0 0 23782002 6 DATA 7 3 23782002 7 EN EN-RSL-HW DATA ERR-T MONIT-ERR ERR-S 23782002 8 ERR-SYS 23782002 9 MEV MEV B B PER-CENT PER-CENT 23782002 10 PER-CENT 23782002 11 17.1 0.3 1.67 0.21 0.83 8.223782002 12 9.5 23782002 13 18.1 0.2 1.82 0.31 0.98 13.723782002 14 9.6 23782002 15 19.0 0.2 1.60 0.30 1.19 16.423782002 16 9.5 23782002 17 ENDDATA 10 0 23782002 18 ENDSUBENT 17 0 2378200299999 ENDENTRY 2 0 2378299999999