ENTRY A0131 20240304 A109A0131 0 1 SUBENT A0131001 20240304 A109A0131 1 1 BIB 11 23 A0131 1 2 TITLE Cross sections of production of 81-Kr in the A0131 1 3 reactions (A>81)Kr(p,pXn)81Kr and 80Kr(n,gamma)81Kr A0131 1 4 REFERENCE (J,SNP,35,638,1982) English translation A0131 1 5 (J,YF,35,1092,1982) A0131 1 6 AUTHOR (V.V.Kuzminov,A.A.Pomanskii) A0131 1 7 INSTITUTE (4ZZZDUB) A0131 1 8 FACILITY (SYNCY,4ZZZDUB) A0131 1 9 METHOD (ACTIV,SITA,EXTB,BCINT) A0131 1 10 SAMPLE This sample had very small impurity Kr-81 and had A0131 1 11 not Kr-85. The gas at a pressure of 520 mm Hg was A0131 1 12 enclosed in a glass ampoule of length 51 cm and A0131 1 13 diameter 10.5 cm. A0131 1 14 INC-SPECT The total flux of protons through the A0131 1 15 ampoule was 5 x 10**16. A0131 1 16 REL-REF (O,41612002,V.V.Kuzminov+,J,YF,35,1092,1982) Neutron A0131 1 17 data compiled in 41612. A0131 1 18 STATUS (TABLE,,V.V.Kuzminov+,J,SNP,35,638,1982) Table 1 A0131 1 19 HISTORY (19820715C) A0131 1 20 (20090114A) BIB section updated A0131 1 21 Subent 003 with neutron incident beam was deleted. A0131 1 22 (20120409U) English translation of 'YF' was added. A0131 1 23 (20190712A) SD: Major corrections in all Subents. A0131 1 24 (20240304A) SD: Correction in Subent 002. A0131 1 25 ENDBIB 23 0 A0131 1 26 NOCOMMON 0 0 A0131 1 27 ENDSUBENT 26 0 A0131 199999 SUBENT A0131002 20240304 A109A0131 2 1 BIB 6 12 A0131 2 2 REACTION (36-KR-0(P,X)36-KR-81,,SIG) A0131 2 3 DECAY-DATA (36-KR-81-G,2.13E+5YR,XR,11.9,0.537) K/X-rays of A0131 2 4 bromine. A0131 2 5 DETECTOR (MWPC) Multiwire proportional counter. The multiwire A0131 2 6 system was mounted inside a cylinder of quartz glass. A0131 2 7 REL-REF (D,,I.R.Barabanov+,J,IZV,37,1186,1973) A0131 2 8 ERR-ANALYS (DATA-ERR) Main source of uncertainties is statistical A0131 2 9 error. A0131 2 10 HISTORY (20190712A) SD: SF3=N+P -> X in REACTION code (5). A0131 2 11 RAD-DET deleted. FACILITY, METHOD moved to Subent 001. A0131 2 12 (20240304A) SD: SF4=Kr-81g -> Kr-81; SF5=CUM deleted A0131 2 13 from REACTION code. Part of data moved to Subent 004. A0131 2 14 ENDBIB 12 0 A0131 2 15 NOCOMMON 0 0 A0131 2 16 DATA 3 1 A0131 2 17 EN DATA DATA-ERR A0131 2 18 MEV MB MB A0131 2 19 600. 35. 3. A0131 2 20 ENDDATA 3 0 A0131 2 21 ENDSUBENT 20 0 A0131 299999 NOSUBENT A0131003 20090114 A065A013100300001 SUBENT A0131004 20240304 A109A0131 4 1 BIB 7 10 A0131 4 2 REACTION (36-KR-86(P,X)36-KR-85-G,CUM,SIG) A0131 4 3 SAMPLE 10% propane was added to the krypton sample. A0131 4 4 DECAY-DATA (36-KR-85-G,10.76YR,B-,,1.) A0131 4 5 DETECTOR (GEMUC) Geiger-Mueller counter of volume 101.6 cm3 A0131 4 6 filled with irradiated krypton to measure the A0131 4 7 rate of decay of 85Kr. A0131 4 8 REL-REF (A,,S.Gas+,J,NP/A,190,501,1972) A0131 4 9 ERR-ANALYS (DATA-ERR) Main source of uncertainties is statistical A0131 4 10 error. A0131 4 11 HISTORY (20240304T) SD: Part of Subent 002. A0131 4 12 ENDBIB 10 0 A0131 4 13 NOCOMMON 0 0 A0131 4 14 DATA 3 1 A0131 4 15 EN DATA DATA-ERR A0131 4 16 MEV MB MB A0131 4 17 600. 36.7 0.8 A0131 4 18 ENDDATA 3 0 A0131 4 19 ENDSUBENT 18 0 A0131 499999 ENDENTRY 4 0 A013199999999