ENTRY A0881 20240919 A119A0881000 1 SUBENT A0881001 20240919 A119A0881001 1 BIB 12 23 A0881001 2 TITLE Excitation functions for the radionuclide 46Sc A0881001 3 produced in the irradiation of 45Sc with deuterons A0881001 4 and 6He A0881001 5 AUTHOR (N.K.Skobelev, A.A.Kulko, V.Kroha, V.Burjan, Z.Hons, A0881001 6 A.V.Daniel, N.A.Demekhina, R.Kalpakchieva, A.Kugler, A0881001 7 J.Mrazek, Yu.E.Penionzhkevich, S.Piskor, Yu.G.Sobolev, A0881001 8 E.Simeckova) A0881001 9 INSTITUTE (4ZZZDUB,3CZRUJF) A0881001 10 REFERENCE (J,JP/G,38,035106,2011) final data A0881001 11 (J,IZV,75,574,2011) prelim. data A0881001 12 (J,BAS,75,538,2011) English translation A0881001 13 REL-REF (M,F0837001,Yu.E.Penionzhkevich+,J,EPJ/A,31,185,2007) A0881001 14 METHOD (BCINT,STTA,ACTIV) A0881001 15 MONITOR (22-TI-0(D,X)23-V-48,,SIG) A0881001 16 DECAY-MON (23-V-48,15.9735D,DG,944.104,0.0776,DG,983.517,0.9998, A0881001 17 DG,1312.096,0.975) A0881001 18 MONIT-REF (,F.Tarkanyi+,R,IAEA-TECDOC-1065,113,1999) A0881001 19 STATUS (TABLE,,A.Kulko,W,KULKO,20110622) A0881001 20 (APRVD) By A.Kulko. A0881001 21 ERR-ANALYS (DATA-ERR) No information about source of uncertainty A0881001 22 HISTORY (20110608C) SB A0881001 23 (20240919A) SD: Small corrections in all Subents. A0881001 24 Subent 004 was split in two. A0881001 25 ENDBIB 23 0 A0881001 26 NOCOMMON 0 0 A0881001 27 ENDSUBENT 26 0 A088100199999 SUBENT A0881002 20240919 A119A0881002 1 BIB 6 22 A0881002 2 REACTION (21-SC-45(D,P)21-SC-46,,SIG) A0881002 3 DECAY-DATA (21-SC-46-G,83.79D,DG,889.3,0.9998,DG,1120.545,0.99987)A0881002 4 DETECTOR (HPGE) All measurements were performed using an HPGe A0881002 5 detector with 50% efficiency with respect to NaI and A0881002 6 the FWHM was 1.8 keV for a gamma energy of 1.3 MeV. A0881002 7 FACILITY (CYCLO,3CZRUJF) the U-120M cyclotron. A0881002 8 (VDGT,4ZZZDUB) EG-5 electrostatic generator. ExperimentA0881002 9 was performed to reduce the energy spread of deuterons A0881002 10 in the subbarrier energy region. A0881002 11 SAMPLE The stack of targets consisting of scandium foils with A0881002 12 thicknesses from 3 to 5 um was installed at the center A0881002 13 of the reaction chamber of U-120M, under the deuteron A0881002 14 beam. The stack also included titanium foils with A0881002 15 thicknesses of 1.8 um, which were used for the monitor A0881002 16 reaction. Aluminium degraders with thicknesses from A0881002 17 5 to 50 um were installed between targets to reduce theA0881002 18 deuteron energy. Deuteron energies of 11.7 to 2.0 MeV A0881002 19 were absorbed in the applied arrays of Sc targets. A0881002 20 Scandium foils, thickness, 2 um, were irradiated by a A0881002 21 deuteron beam of EG-5 with an energy varying from A0881002 22 0.9 to 2.5MeV. A0881002 23 HISTORY (20240919U) SD: BIB updated. A0881002 24 ENDBIB 22 0 A0881002 25 NOCOMMON 0 0 A0881002 26 DATA 4 18 A0881002 27 EN EN-ERR DATA DATA-ERR A0881002 28 MEV MEV MB MB A0881002 29 11.59 0.12 217. 8.6 A0881002 30 10.41 0.14 243. 6.8 A0881002 31 9.0 0.17 292. 11.1 A0881002 32 7.26 0.23 344. 9.3 A0881002 33 7.22 0.23 358. 2.2 A0881002 34 5.82 0.26 399. 3.2 A0881002 35 5.8 0.26 369. 3.3 A0881002 36 4.63 0.33 293. 4.5 A0881002 37 3.91 0.33 248. 2.2 A0881002 38 3.52 0.39 169. 3.6 A0881002 39 2.88 0.41 135. 0.4 A0881002 40 2.51 0.49 79.7 4.1 A0881002 41 2.46 0.05 38.0 0.6 A0881002 42 2.27 0.48 60.1 2.4 A0881002 43 2.00 0.62 28.6 1.2 A0881002 44 1.95 0.05 8.2 0.2 A0881002 45 1.45 0.05 0.8 0.065 A0881002 46 0.81 0.05 0.00137 0.0005 A0881002 47 ENDDATA 20 0 A0881002 48 ENDSUBENT 47 0 A088100299999 SUBENT A0881003 20240919 A119A0881003 1 BIB 6 17 A0881003 2 REACTION (21-SC-45(D,T)21-SC-44,,SIG) A0881003 3 DECAY-DATA (21-SC-44-M,58.69HR,DG,271.13,0.867) A0881003 4 (21-SC-44-G,3.927HR,DG,1157.031,0.999) A0881003 5 DETECTOR (HPGE) All measurements were performed using an HPGe A0881003 6 detector with 50% efficiency with respect to NaI and A0881003 7 the FWHM was 1.8 keV for a gamma energy of 1.3 MeV. A0881003 8 FACILITY (CYCLO,3CZRUJF) the U-120M cyclotron A0881003 9 SAMPLE The stack of targets consisting of scandium foils with A0881003 10 thicknesses from 3 to 5 mum was installed at the centerA0881003 11 of the reaction chamber, under the deuteron beam. A0881003 12 The stack also included titanium foils with thicknessesA0881003 13 of 1.8 mum, which were used for the monitor reaction. A0881003 14 Aluminium degraders with thicknesses from 5 to 50 mum A0881003 15 were installed between targets to reduce the deuteron A0881003 16 energy. Deuteron energies of 11.7 to 2.0 MeV were A0881003 17 absorbed in the applied arrays of Sc targets. A0881003 18 HISTORY (20240919U) SD: BIB updated. A0881003 19 ENDBIB 17 0 A0881003 20 NOCOMMON 0 0 A0881003 21 DATA 5 4 A0881003 22 EN EN-ERR DATA DATA-ERR DATA-MAX A0881003 23 MEV MEV MB MB MB A0881003 24 11.59 0.12 3.18 0.34 A0881003 25 10.41 0.14 1.78 0.03 A0881003 26 9.0 0.17 1.24 0.14 A0881003 27 7.26 0.23 0.014 A0881003 28 ENDDATA 6 0 A0881003 29 ENDSUBENT 28 0 A088100399999 SUBENT A0881004 20240919 A119A0881004 1 BIB 7 20 A0881004 2 REACTION (21-SC-45(2-HE-6,X)21-SC-46,,SIG) A0881004 3 DECAY-DATA (21-SC-46-G,83.79D,DG,889.3,0.9998,DG,1120.545,0.99987)A0881004 4 METHOD (INTB) 6He A0881004 5 DETECTOR (HPGE) HPGe detectors with an energy resolution of A0881004 6 approx. 1.2 keV for E(g)=662 keV were used in the A0881004 7 measurements. A0881004 8 FACILITY (VDGT,4ZZZDUB) A 6He beam was obtained at the DRIBs A0881004 9 accelerator complex for radioactive beams, which is a A0881004 10 tandem of two accelerators U-400M and U-400 (ISOL). A0881004 11 SAMPLE The target stack consisted of six Sc foils with A0881004 12 thicknesses of 3 to 5 um. The first stack was A0881004 13 irradiated with a calculated 6He energy of 20 MeV. A0881004 14 A stack of three Sc foils was irradiated by a 6He beam A0881004 15 with an energy of ions incident on the stack of about A0881004 16 23 MeV. A0881004 17 In both arrays, Al foils with different thicknesses A0881004 18 were placed between the Sc targets to measure the 6He A0881004 19 energy. A0881004 20 HISTORY (20240919A) SD: Subent was split in two (see A0881004 21 Subent 005). A0881004 22 ENDBIB 20 0 A0881004 23 NOCOMMON 0 0 A0881004 24 DATA 3 9 A0881004 25 EN DATA DATA-ERR A0881004 26 MEV MB MB A0881004 27 4.86 33.9 7. A0881004 28 5.43 39.1 5. A0881004 29 7.19 172. 15. A0881004 30 8.68 207. 23. A0881004 31 9.73 196. 14. A0881004 32 11.46 183. 11. A0881004 33 21.3 186. 13. A0881004 34 22.1 178. 16. A0881004 35 22.9 191. 18. A0881004 36 ENDDATA 11 0 A0881004 37 ENDSUBENT 36 0 A088100499999 SUBENT A0881005 20240919 A119A0881005 1 BIB 7 19 A0881005 2 REACTION (21-SC-45(2-HE-6,A)21-SC-47,,SIG) A0881005 3 DECAY-DATA (21-SC-47,3.3492D,DG,159.377,0.683) A0881005 4 METHOD (INTB)HE-6 A0881005 5 DETECTOR (HPGE) HPGe detectors with an energy resolution of A0881005 6 approx. 1.2 keV for E(g)=662 keV were used in the A0881005 7 measurements. A0881005 8 FACILITY (VDGT,4ZZZDUB) A 6He beam was obtained at the DRIBs A0881005 9 accelerator complex for radioactive beams, which is a A0881005 10 tandem of two accelerators U-400M and U-400 (ISOL). A0881005 11 SAMPLE The target stack consisted of six Sc foils with A0881005 12 thicknesses of 3 to 5 um. The first stack was A0881005 13 irradiated with a calculated 6He energy of 20 MeV. A0881005 14 A stack of three Sc foils was irradiated by a 6He beam A0881005 15 with an energy of ions incident on the stack of about A0881005 16 23 MeV. A0881005 17 In both arrays, Al foils with different thicknesses A0881005 18 were placed between the Sc targets to measure the 6He A0881005 19 energy. A0881005 20 HISTORY (20240919T) SD: Part of Subent 004. A0881005 21 ENDBIB 19 0 A0881005 22 NOCOMMON 0 0 A0881005 23 DATA 3 3 A0881005 24 EN DATA DATA-ERR A0881005 25 MEV MB MB A0881005 26 21.3 19.09 4.0 A0881005 27 22.1 20.4 4.5 A0881005 28 22.9 17.4 3.5 A0881005 29 ENDDATA 5 0 A0881005 30 ENDSUBENT 29 0 A088100599999 ENDENTRY 5 0 A088199999999