ENTRY            C1449   20081020                             C089C144900000001 
SUBENT        C1449001   20081020                             C089C144900100001 
BIB                 10         35                                 C144900100002 
INSTITUTE  (1CANTMF,1CANMCM,1USACSM,1CANSFU,2EIREIR,2GERLMU,      C144900100003 
           1CANCAN,2BLGLEU) + University de Catalunya, Spain +    C144900100004 
            University of York, UK                                C144900100005 
REFERENCE  (J,PRL,96,252501,2006)                                 C144900100006 
AUTHOR     (C.Ruiz,A.Parikh,J.Jose,L.Buchmann,J.A.Caggiano,       C144900100007 
            A.A.Chen,J.A.Clark,H.Crawford,B.Davids,J.M.D'Auria,   C144900100008 
            C.Davis,C.Deibel,L.Erikson,L.Fogarty,D.Frekers,       C144900100009 
            U.Greife,A.Hussein,D.A.Hutcheon,M.Huyse,C.Jewett,     C144900100010 
            A.M.Laird,R.Lewis,P.Mumby-Croft,A.Olin,D.F.Ottewell,  C144900100011 
            C.V.Ouellet,P.Parker,J.Pearson,G.Ruprecht,M.Trinczek, C144900100012 
            C.Vockenhuber,C.Wrede)                                C144900100013 
TITLE      Measurement of the E(c.m.)=184 keV Resonance Strength  C144900100014 
            in the 26gAl(p,gamma)27Si Reaction                    C144900100015 
FACILITY   (FRS,1CANTMF) the DRAGON recoil separator in the ISAC  C144900100016 
            radioactive ion beam facility at TRIUMF.              C144900100017 
INC-SOURCE A high-power SiC target was bombarded with up to 70    C144900100018 
            microA of 500 MeV protons from TRIUMF's sector        C144900100019 
            focussing cyclotron, producing radioactive 26gAl      C144900100020 
DETECTOR   (BGO) The DRAGON facility consists of a windowless     C144900100021 
            hydrogen-recirculating gas target surrounded by an    C144900100022 
            array of 30 bismuth germanate (BGO) detectors, and a  C144900100023 
            two-stage electromagnetic recoil separator.           C144900100024 
           (SIBAR) The total separator length from the center of  C144900100025 
            the gas cell to the final m=q focus is 20.42 m, with  C144900100026 
            a double-sided silicon strip detector (DSSD) placed   C144900100027 
            65 cm downstream from the focus. A collimated silicon C144900100028 
            surface barrier detector placed at 30 degree from the C144900100029 
            center of the gas cell was used to detect protons     C144900100030 
            elastically scattered by the incoming beam during the C144900100031 
            run as a means of normalization.                      C144900100032 
SAMPLE     A gas-target pressure of 6 Torr was maintained to      C144900100033 
            within +/- 1.6%.                                      C144900100034 
METHOD     (COINC)                                                C144900100035 
HISTORY    (20060718C) DR                                         C144900100036 
           (20081020A) BIB update.                                C144900100037 
ENDBIB              35          0                                 C144900100038 
NOCOMMON             0          0                                 C144900100039 
ENDSUBENT           38          0                                 C144900199999 
SUBENT        C1449002   20081020                             C089C144900200001 
BIB                  4          5                                 C144900200002 
REACTION   (13-AL-26(P,G),,WID/STR)                               C144900200003 
ERR-ANALYS (ERR-S) Statistical error                              C144900200004 
           (ERR-SYS) Systematical error                           C144900200005 
STATUS     (TABLE) Data taken from Table 1                        C144900200006 
HISTORY    (20081020A) Target nucleus corrected.                  C144900200007 
ENDBIB               5          0                                 C144900200008 
NOCOMMON             0          0                                 C144900200009 
DATA                 4          2                                 C144900200010 
EN-RES     DATA       ERR-S      ERR-SYS                          C144900200011 
MEV        MICRO-EV   MICRO-EV   MICRO-EV                         C144900200012 
5.226      35.        4.         5.                               C144900200013 
5.122      36.        8.         6.                               C144900200014 
ENDDATA              4          0                                 C144900200015 
ENDSUBENT           14          0                                 C144900299999 
ENDENTRY             2          0                                 C144999999999