ENTRY C2765 20220718 C221C2765 0 1 SUBENT C2765001 20220718 C221C2765 1 1 BIB 9 20 C2765 1 2 TITLE Excitation function of 54Fe(p,a)51Mn from 9.5 MeV to C2765 1 3 18 MeV C2765 1 4 AUTHOR (W.Lin,J.T.Wilkinson,K.E.Barrett,T.E.Barnhart,M.Gott, C2765 1 5 K.V.Becker,A.M.Clark,A.Miller,G.Brown,M.Deluca, C2765 1 6 R.Bartsch,G.F.Peaslee,J.W.Engle) C2765 1 7 INSTITUTE (1USAWIS,1USANOT,1USAANL) C2765 1 8 REFERENCE (J,NP/A,1021,122424,2022) C2765 1 9 FACILITY (VDGT,1USANOT) The 11MV FN Tandem Van de Graaff C2765 1 10 accelerator at University of Notre Dame's Nuclear C2765 1 11 Science Laboratory (ND) was ued in this experiment C2765 1 12 MONITOR 1(29-CU-63(P,N)30-ZN-63,,SIG) C2765 1 13 2(29-CU-63(P,2N)30-ZN-62,,SIG) C2765 1 14 3(29-CU-65(P,N)30-ZN-65,,SIG) C2765 1 15 DECAY-MON 1(30-ZN-63,38.47MIN,DG,669.62,0.082) C2765 1 16 2(30-ZN-62,9.193HR,DG,596.56,0.260) C2765 1 17 3(30-ZN-65,243.93D,DG,1115.54,0.5004) C2765 1 18 ERR-ANALYS (ERR-1) Uncertainty if HPGe efficiency calibration C2765 1 19 (ERR-2) Uncertainty from beam current measurement C2765 1 20 (ERR-T) Total uncertainty C2765 1 21 HISTORY (20220718C) Compiled by S.H. C2765 1 22 ENDBIB 20 0 C2765 1 23 COMMON 3 3 C2765 1 24 EN-RSL ERR-1 ERR-2 C2765 1 25 MEV PER-CENT PER-CENT C2765 1 26 0.1 6.0 5.0 C2765 1 27 ENDCOMMON 3 0 C2765 1 28 ENDSUBENT 27 0 C2765 199999 SUBENT C2765002 20220718 C221C2765 2 1 BIB 7 19 C2765 2 2 REACTION 1(26-FE-54(P,A)25-MN-51,,SIG) C2765 2 3 2(26-FE-54(P,A)25-MN-51,,SIG) C2765 2 4 3(26-FE-54(P,A)25-MN-51,,SIG,,AV) C2765 2 5 METHOD Cross section determined after 51Mn->51Cr decay from C2765 2 6 51Cr activity C2765 2 7 DETECTOR (HPGE) Samples were measured in low background C2765 2 8 counting station at Notre Dame (ND) within NSL using C2765 2 9 a Canberra model GC3518 HPGe detector. C2765 2 10 (HPGE) - Canberra model C1519 HPGe was used at C2765 2 11 University of Wisconsin at Madison (UWM) for 51Cr C2765 2 12 measurement C2765 2 13 RAD-DET (24-CR-51,DG) C2765 2 14 DECAY-DATA (25-MN-51,46.2MIN) C2765 2 15 (24-CR-51,27.704D,DG,320.08,0.0991) C2765 2 16 COMMENT 1Cross section determined from 51Cr activity at UWM C2765 2 17 2Cross section determined from 51Cr activity at ND C2765 2 18 3Weighted average from 51Cr activity at UWM and ND C2765 2 19 STATUS (TABLE) Data taken from tab.2 of the reference C2765 2 20 (COREL,C2765003) Data determined with 51Mn activity C2765 2 21 ENDBIB 19 0 C2765 2 22 NOCOMMON 0 0 C2765 2 23 DATA 7 10 C2765 2 24 EN DATA 1ERR-T 1DATA 2ERR-T 2DATA 3C2765 2 25 ERR-T 3 C2765 2 26 MEV MB MB MB MB MB C2765 2 27 MB C2765 2 28 17.9 41.5 3.7 41.5 4.7 41.5 C2765 2 29 3.1 C2765 2 30 16.9 39.6 3.6 43.2 4.8 40.5 C2765 2 31 3.7 C2765 2 32 15.9 37.7 3.3 37.8 2.9 40.7 C2765 2 33 8.4 C2765 2 34 14.9 33.2 3.1 33.7 3.8 33.4 C2765 2 35 2.5 C2765 2 36 13.9 31.9 3.0 35.0 3.5 33.1 C2765 2 37 3.2 C2765 2 38 12.9 22.7 2.1 23.4 2.5 22.9 C2765 2 39 1.8 C2765 2 40 11.9 15.9 1.5 16.4 2.1 16.0 C2765 2 41 1.2 C2765 2 42 10.9 7.44 0.74 7.88 1.45 7.49 C2765 2 43 0.59 C2765 2 44 9.9 2.29 0.22 2.90 0.56 2.33 C2765 2 45 0.28 C2765 2 46 9.4 0.83 0.09 1.03 0.41 0.84 C2765 2 47 0.08 C2765 2 48 ENDDATA 24 0 C2765 2 49 ENDSUBENT 48 0 C2765 299999 SUBENT C2765003 20220718 C221C2765 3 1 BIB 4 7 C2765 3 2 REACTION (26-FE-54(P,A)25-MN-51,,SIG) C2765 3 3 DETECTOR (HPGE) Samples were measured in low background C2765 3 4 counting station within ND NSL using a Canberra model C2765 3 5 GC3518 HPGe detector. C2765 3 6 DECAY-DATA (25-MN-51,46.2MIN,DG,749.07,0.265) C2765 3 7 STATUS (TABLE) Data taken from tab.2 of the reference C2765 3 8 (COREL,C2765002) Data determined with 51Cr activity C2765 3 9 ENDBIB 7 0 C2765 3 10 NOCOMMON 0 0 C2765 3 11 DATA 3 3 C2765 3 12 EN DATA ERR-T C2765 3 13 MEV MB MB C2765 3 14 17.9 26.4 12.9 C2765 3 15 16.9 52.5 18.6 C2765 3 16 14.9 18.5 10.2 C2765 3 17 ENDDATA 5 0 C2765 3 18 ENDSUBENT 17 0 C2765 399999 ENDENTRY 3 0 C276599999999