ENTRY C2852 20221109 C225C2852000 1 SUBENT C2852001 20221109 C225C2852001 1 BIB 9 15 C2852001 2 TITLE A Further Test of the Shell Model C2852001 3 AUTHOR (J.S.King,W.C.Parkinson) C2852001 4 REFERENCE (J,PR,88,141,1952) C2852001 5 #doi:10.1103/PhysRev.88.141 C2852001 6 REL-REF (O,C2847001,J.S.King,J,PR,89,1080,1953) C2852001 7 (O,C2851001,W.C.Parkinson,J,PR,87,387(2),1952) C2852001 8 INSTITUTE (1USAMHG) C2852001 9 FACILITY (ACCEL,1USAMHG) C2852001 10 SAMPLE The target, a foil of silver chloride 0.0003 inch C2852001 11 thick, was rolled from a pure silver chloride crystal. C2852001 12 ERR-ANALYS (ERR-S) The vertical lines through the experimental C2852001 13 points represent the standard deviations as C2852001 14 determined from the total number of counts and do not C2852001 15 represent the overall uncertainty of the data. C2852001 16 HISTORY (20221109C) BP C2852001 17 ENDBIB 15 0 C2852001 18 COMMON 1 3 C2852001 19 EN-CM C2852001 20 MEV C2852001 21 6.90 C2852001 22 ENDCOMMON 3 0 C2852001 23 ENDSUBENT 22 0 C285200199999 SUBENT C2852002 20221109 C225C2852002 1 BIB 2 3 C2852002 2 REACTION (17-CL-35(D,P)17-CL-36,PAR,DA,,REL) C2852002 3 STATUS (CURVE,,J.S.King+,J,PR,88,141,1952) C2852002 4 Fig. 1, page 142 of J,PR,88,141,1952. C2852002 5 ENDBIB 3 0 C2852002 6 COMMON 1 3 C2852002 7 E-LVL C2852002 8 MEV C2852002 9 0.0 C2852002 10 ENDCOMMON 3 0 C2852002 11 DATA 3 11 C2852002 12 ANG-CM DATA-CM ERR-S C2852002 13 ADEG ARB-UNITS ARB-UNITS C2852002 14 0.3681 64.33 8.040 C2852002 15 10.94 41.54 3.916 C2852002 16 20.47 63.69 3.711 C2852002 17 25.27 84.97 5.569 C2852002 18 30.39 99.66 3.299 C2852002 19 35.56 94.55 5.776 C2852002 20 40.76 74.39 3.298 C2852002 21 51.14 40.68 3.299 C2852002 22 61.50 19.12 3.297 C2852002 23 71.39 22.72 2.885 C2852002 24 81.92 18.90 3.092 C2852002 25 ENDDATA 13 0 C2852002 26 ENDSUBENT 25 0 C285200299999 SUBENT C2852003 20221109 C225C2852003 1 BIB 4 12 C2852003 2 REACTION (17-CL-35(D,P)17-CL-36,PAR,DA,,REL) C2852003 3 METHOD The background counting rate was obtained by C2852003 4 substituting for the silver chloride target a foil of C2852003 5 pure silver containing very nearly the same amount of C2852003 6 silver per square centimeter as that of the target. C2852003 7 It was negligible at all angles except 0 degree, C2852003 8 where it accounted for 35 percent of the total C2852003 9 counting rate. C2852003 10 CORRECTION After subtracting from each point the constant C2852003 11 "background" counting rate at 65 degrees. C2852003 12 STATUS (CURVE,,J.S.King+,J,PR,88,141,1952) C2852003 13 Fig. 2, page 142 of J,PR,88,141,1952. C2852003 14 ENDBIB 12 0 C2852003 15 COMMON 1 3 C2852003 16 E-LVL C2852003 17 MEV C2852003 18 0.0 C2852003 19 ENDCOMMON 3 0 C2852003 20 DATA 3 10 C2852003 21 ANG-CM DATA-CM ERR-S C2852003 22 ADEG ARB-UNITS ARB-UNITS C2852003 23 10.89 31.82 3.636 C2852003 24 20.69 58.51 3.850 C2852003 25 25.55 82.44 5.991 C2852003 26 30.62 99.53 3.209 C2852003 27 35.77 94.16 5.776 C2852003 28 41.00 71.03 4.066 C2852003 29 51.05 30.13 4.277 C2852003 30 61.11 2.705 3.209 C2852003 31 71.43 7.789 2.996 C2852003 32 81.52 3.035 2.568 C2852003 33 ENDDATA 12 0 C2852003 34 ENDSUBENT 33 0 C285200399999 ENDENTRY 3 0 C285299999999