ENTRY C2863 20221220 C234C2863000 1 SUBENT C2863001 20221220 C234C2863001 1 BIB 8 17 C2863001 2 TITLE 18O(alpha,8He)14O reaction C2863001 3 AUTHOR (J.Jaenecke,F.D.Becchetti,L.T.Chua,A.M.VanderMolen) C2863001 4 INSTITUTE (1USAMHG) C2863001 5 REFERENCE (J,PR/C,11,2114,1975) C2863001 6 #doi:10.1103/PhysRevC.11.2114 C2863001 7 FACILITY (CYCLO,1USAMHG) The 2 m variable energy cyclotron C2863001 8 DETECTOR (TELES,PROPC,SOLST) The reaction products were C2863001 9 detected and identified in the focal plane of C2863001 10 analyzing magnet using a special position-sensitive C2863001 11 dE-E counter telescope. The focal-plane detection C2863001 12 system consisted of two gas-proportional dE counters C2863001 13 providing the signals dE1 (or alternately x1), and C2863001 14 dE2 backed by a 20 mm high by 50 mm long solid state C2863001 15 position-sensitive detector of 350 mu-m thickness. C2863001 16 SAMPLE Targets consisted of oxidized nickel foils C2863001 17 (140 mu-g/cm2 18O and 450 mu-g/cm2 Ni). C2863001 18 HISTORY (20221220C) OG C2863001 19 ENDBIB 17 0 C2863001 20 NOCOMMON 0 0 C2863001 21 ENDSUBENT 20 0 C286300199999 SUBENT C2863002 20221220 C234C2863002 1 BIB 4 4 C2863002 2 REACTION (8-O-18(A,2-HE-8)8-O-14,PAR,DA) C2863002 3 EN-SEC (E-LVL,8-O-14) C2863002 4 ERR-ANALYS (DATA-ERR) No information on source of uncertainties. C2863002 5 STATUS (TABLE,,J.Jaenecke+,J,PR/C,11,2114,1975) Text at p.2114C2863002 6 ENDBIB 4 0 C2863002 7 NOCOMMON 0 0 C2863002 8 DATA 5 1 C2863002 9 EN E-LVL ANG DATA DATA-ERR C2863002 10 MEV MEV ADEG NB/SR NB/SR C2863002 11 58. 0. 8. 40. 15. C2863002 12 ENDDATA 3 0 C2863002 13 ENDSUBENT 12 0 C286300299999 ENDENTRY 2 0 C286399999999