ENTRY L0195 20141118 L025L0195 0 1 SUBENT L0195001 20141118 L025L0195 1 1 BIB 10 30 L0195 1 2 TITLE Compton scattering from 6Li at 86 MeV L0195 1 3 AUTHOR (L.S.Myers,M.W.Ahmed,G.Feldman,A.Kafkarkou, L0195 1 4 D.P.Kendellen,I.Mazumdar,J.M.Mueller,M.H.Sikora, L0195 1 5 H.R.Weller,W.R.Zimmerman) L0195 1 6 INSTITUTE (1USADKE,1USATNL,1USAGWU,3INDTAT,1USANCC) L0195 1 7 REFERENCE (J,PR/C,90,027603,2014) L0195 1 8 FACILITY (ESTRG,1USATNL) Experiment performed at the High L0195 1 9 Intensity Gamma-Ray Source (HIGS) at Triangle L0195 1 10 University Nuclear Laboratiry in Durham L0195 1 11 DETECTOR (NAICR) Array of eight large-volume NaI(Tl) detectors L0195 1 12 placed at roughly equally spaced angles from 40deg to L0195 1 13 160deg.Each NaI(Tl) detector core measures L0195 1 14 approximately 25.4 cm in diameter and 30.5 cm long. L0195 1 15 Surrounding the core detector is a segmented NaI(Tl) L0195 1 16 annular detector that is 7.5 cm thick and 30.5 cm L0195 1 17 long and is designed as an anticoincidence shield. L0195 1 18 The detector-response line shapes from the core L0195 1 19 detectors had a full width at half maximum of approx. L0195 1 20 6% at 60 MeV L0195 1 21 METHOD (TOF) Time of flight method was used to select prompt L0195 1 22 gamma ray events to reduce background L0195 1 23 INC-SOURCE (LCS) Photons were produced via Compton L0195 1 24 backscattering of free-electron laser (FEL) photons L0195 1 25 from relativistic electrons in one of the two L0195 1 26 straight sections of electron storage ring. L0195 1 27 ERR-ANALYS (ERR-S) Statistical uncertainty L0195 1 28 (ERR-SYS) Systematic uncertainty L0195 1 29 (ERR-1) Uncertainty in no.of incident photons L0195 1 30 (ERR-2) Uncertainty in detector acceptance L0195 1 31 HISTORY (20141118C) Compiled by S.H. L0195 1 32 ENDBIB 30 0 L0195 1 33 COMMON 4 3 L0195 1 34 EN EN-RSL ERR-1 ERR-2 L0195 1 35 MEV PER-CENT PER-CENT PER-CENT L0195 1 36 86.0 6.0 3.0 3.7 L0195 1 37 ENDCOMMON 3 0 L0195 1 38 ENDSUBENT 37 0 L0195 199999 SUBENT L0195002 20141118 L025L0195 2 1 BIB 3 5 L0195 2 2 REACTION (8-O-16(G,EL)8-O-16,,DA) L0195 2 3 STATUS (TABLE) Data taken from tab. 1 of the reference L0195 2 4 SAMPLE The oxygen target consisted of distilled water in a L0195 2 5 Lucite cylinder 11.3 cm long and 5.0 cm in diameter, L0195 2 6 yielding an oxygen target thickness of 11.3+-0.1 g/cm2.L0195 2 7 ENDBIB 5 0 L0195 2 8 NOCOMMON 0 0 L0195 2 9 DATA 4 7 L0195 2 10 ANG DATA ERR-S ERR-SYS L0195 2 11 ADEG NB/SR NB/SR NB/SR L0195 2 12 40.0 1062.0 63.0 58.0 L0195 2 13 55.0 739.0 47.0 38.0 L0195 2 14 75.0 667.0 53.0 34.0 L0195 2 15 90.0 527.0 51.0 27.0 L0195 2 16 110.0 634.0 78.0 33.0 L0195 2 17 145.0 622.0 64.0 32.0 L0195 2 18 159.0 527.0 45.0 27.0 L0195 2 19 ENDDATA 9 0 L0195 2 20 ENDSUBENT 19 0 L0195 299999 SUBENT L0195003 20141118 L025L0195 3 1 BIB 3 6 L0195 3 2 REACTION (3-LI-6(G,EL)3-LI-6,,DA) L0195 3 3 STATUS (TABLE) Data taken from tab. 1 of the reference L0195 3 4 SAMPLE The 6Li target cell consists of a polyvinyl chloride L0195 3 5 cylinder with PVC and Al foil end caps. 6Li sample L0195 3 6 measures 12.7 cm in length with a diameter of 4.1 cm L0195 3 7 for a target thickness of 5.84+-0.06 g/cm2. L0195 3 8 ENDBIB 6 0 L0195 3 9 NOCOMMON 0 0 L0195 3 10 DATA 4 7 L0195 3 11 ANG DATA ERR-S ERR-SYS L0195 3 12 ADEG NB/SR NB/SR NB/SR L0195 3 13 40.0 203.0 18.0 10.0 L0195 3 14 55.0 147.0 11.0 7.0 L0195 3 15 75.0 140.0 12.0 7.0 L0195 3 16 90.0 160.0 13.0 8.0 L0195 3 17 110.0 146.0 20.0 7.0 L0195 3 18 145.0 167.0 18.0 8.0 L0195 3 19 159.0 172.0 12.0 9.0 L0195 3 20 ENDDATA 9 0 L0195 3 21 ENDSUBENT 20 0 L0195 399999 ENDENTRY 3 0 L019599999999