ENTRY            O2318   20170122                             O060O231800000001 
SUBENT        O2318001   20170122                             O060O231800100001 
BIB                  9         15                                 O231800100002 
TITLE      Constraints on the alpha+nucleus optical-model         O231800100003 
           potential via alpha-induced reaction studies on 108Cd. O231800100004 
AUTHOR     (P.Scholz,F.Heim,J.Mayer,C.Muenker,L.Netterdon,        O231800100005 
           F.Wombacher,A.Zilges)                                  O231800100006 
INSTITUTE  (2GERKLN,2GERBON)                                      O231800100007 
REFERENCE  (J,PL/B,761,247,2016)                                  O231800100008 
REL-REF    (I,D4271001,Z.Halasz+,J,PR/C,85,025804,2012)           O231800100009 
           (I,O1959001,A.Sauerwein+,J,PR/C,84,045808,2011)        O231800100010 
FACILITY   (VDGT,2GERKLN) 10 MV FN tandem ion accelerator at the  O231800100011 
           Institute for Nuclear Physics in Cologne.              O231800100012 
SAMPLE     The targets, Cd metal with an enriched 108Cdisotope    O231800100013 
           abundance of 70.6%, thickness of 867 mug/cm**2         O231800100014 
           and 725 mug/cm**2, was used.                           O231800100015 
HISTORY    (20170122C) SB                                         O231800100016 
ERR-ANALYS (DATA-ERR).No information on source of uncertainty     O231800100017 
ENDBIB              15          0                                 O231800100018 
COMMON               1          3                                 O231800100019 
EN-ERR                                                            O231800100020 
KEV                                                               O231800100021 
31.                                                               O231800100022 
ENDCOMMON            3          0                                 O231800100023 
ENDSUBENT           22          0                                 O231800199999 
SUBENT        O2318002   20170122                             O060O231800200001 
BIB                  4          5                                 O231800200002 
REACTION   (48-CD-108(A,G)50-SN-112,,SIG)                         O231800200003 
METHOD     (GSPEC)                                                O231800200004 
DETECTOR   (HPGE) 14 HPGe detectors                               O231800200005 
           (BGO)                                                  O231800200006 
STATUS     (TABLE).Table 2 of  J,PL/B,761,247,2016                O231800200007 
ENDBIB               5          0                                 O231800200008 
NOCOMMON             0          0                                 O231800200009 
DATA                 3          4                                 O231800200010 
EN-CM      DATA       DATA-ERR                                    O231800200011 
KEV        MB         MB                                          O231800200012 
13479.     1.36       0.41                                        O231800200013 
12979.     1.09       0.34                                        O231800200014 
12478.     0.82       0.25                                        O231800200015 
11978.     0.61       0.19                                        O231800200016 
ENDDATA              6          0                                 O231800200017 
ENDSUBENT           16          0                                 O231800299999 
SUBENT        O2318003   20170122                             O060O231800300001 
BIB                  6         24                                 O231800300002 
REACTION   (48-CD-108(A,N)50-SN-111,,SIG)                         O231800300003 
METHOD     (ACTIV)                                                O231800300004 
DETECTOR   (HPGE) 2 HPGe detectors                                O231800300005 
DECAY-DATA (50-SN-111,35.4MIN,DG,761.97,0.0148,DG,954.05,0.0051,  O231800300006 
           DG,1152.98,0.0265,DG,1610.47,0.0131)                   O231800300007 
STATUS     (TABLE).Table 4 of  J,PL/B,761,247,2016                O231800300008 
FLAG       (1.).Cross-section values measured with CloverA        O231800300009 
           detector.                                              O231800300010 
           (2.).Cross-section values measured with CloverB        O231800300011 
           detector.                                              O231800300012 
           (3.).Cross-section values measured with both Clover    O231800300013 
           detector.                                              O231800300014 
           (4.).Cross-section values measured with CloverA        O231800300015 
           detector,first measurement.                            O231800300016 
           (5.).Cross-section values measured with CloverB        O231800300017 
           detector,first measurement.                            O231800300018 
           (6.).Cross-section values measured with CloverA        O231800300019 
           detector,second measurement.                           O231800300020 
           (7.).Cross-section values measured with CloverB        O231800300021 
           detector,second measurement.                           O231800300022 
           (8.).Cross-section values measured with both Clover    O231800300023 
           detector,first measurement.                            O231800300024 
           (9.).Cross-section values measured with both Clover    O231800300025 
           detector,second measurement.                           O231800300026 
ENDBIB              24          0                                 O231800300027 
NOCOMMON             0          0                                 O231800300028 
DATA                 4         15                                 O231800300029 
EN-CM      DATA       DATA-ERR   FLAG                             O231800300030 
KEV        MB         MB         NO-DIM                           O231800300031 
13479.     59.59      5.69       1.                               O231800300032 
13479.     57.30      5.48       2.                               O231800300033 
12979.     34.70      3.33       4.                               O231800300034 
12979.     33.45      3.22       5.                               O231800300035 
12979.     39.99      3.81       6.                               O231800300036 
12979.     38.45      3.67       7.                               O231800300037 
12478.     12.63      1.20                                        O231800300038 
11978.      6.57      0.63       8.                               O231800300039 
11978.      6.42      0.62       9.                               O231800300040 
11677.      3.80      0.36       3.                               O231800300041 
11377.      1.93      0.19       3.                               O231800300042 
11077.      1.18      0.12       3.                               O231800300043 
10776.      0.53      0.07       3.                               O231800300044 
10476.      0.31      0.07       3.                               O231800300045 
10176.      0.14      0.06       3.                               O231800300046 
ENDDATA             17          0                                 O231800300047 
ENDSUBENT           46          0                                 O231800399999 
ENDENTRY             3          0                                 O231899999999