ENTRY O2446 20221224 O092O2446 0 1 SUBENT O2446001 20221224 O092O2446 1 1 BIB 8 19 O2446 1 2 TITLE Cross section measurements of proton capture O2446 1 3 reactions on Se isotopes relevant to the O2446 1 4 astrophysical p process O2446 1 5 AUTHOR (V.Foteinou,S.Harissopulos,M.Axiotis,A.Lagoyannis, O2446 1 6 G.Provatas, A.Spyrou,G.Perdikakis,Ch.Zarkadas, O2446 1 7 P.Demetriou) O2446 1 8 INSTITUTE (2GRCATH,3ZZZIAE) O2446 1 9 REFERENCE (J,PR/C,97,035806,2018) O2446 1 10 #doi:10.1103/PhysRevC.97.035806 O2446 1 11 (J,NP/A,719,C115,2003) prelim. data of 80Se(p,gamma) O2446 1 12 METHOD (BCINT) O2446 1 13 INC-SPECT The corresponding effective beam energies in the O2446 1 14 center-of-mass system is deduced from the incident O2446 1 15 proton beam energy and its energy loss at the center ofO2446 1 16 the target. O2446 1 17 CORRECTION Electron screening correction applied. O2446 1 18 HISTORY (20190514C) VS O2446 1 19 (20191226U) SD: Ref. NP/A,719,C115,2003 added. O2446 1 20 (20221224A) SD: Correction in Subent 002. O2446 1 21 ENDBIB 19 0 O2446 1 22 NOCOMMON 0 0 O2446 1 23 ENDSUBENT 22 0 O2446 199999 SUBENT O2446002 20221224 O092O2446 2 1 BIB 8 21 O2446 2 2 REACTION 1(34-SE-78(P,G)35-BR-79,,SIG) O2446 2 3 2(34-SE-78(P,G)35-BR-79,,SIG,,SFC) O2446 2 4 FACILITY (DYNAM,2GERTHS) 4-MV single-ended Dynamitron. O2446 2 5 DETECTOR (HPGE) Four hyper-pure Ge(HPGe) detectors. The relativeO2446 2 6 efficiency was almost 100 % for the three of them and O2446 2 7 76% for the fourth one. The Compton background O2446 2 8 suppressed by using four BGO crystals surrounding the O2446 2 9 Ge detectors. O2446 2 10 SAMPLE The effective areal density 90 +- 9 ug/cm2 O2446 2 11 (34-SE-78,ENR=0.978) O2446 2 12 ANALYSIS (INTAD) Gamma-singles spectra measured at eight O2446 2 13 angles with respect to the beam direction. O2446 2 14 ERR-ANALYS (ERR-T) Total uncertainty calculated from the error O2446 2 15 propagation of: O2446 2 16 (ERR-1) thickness of the target - 10% O2446 2 17 (ERR-2) detector efficiency - 5% O2446 2 18 (ERR-3) accumulated charge - 3% O2446 2 19 (ERR-4,3.,30.) total angle-integrated yield. O2446 2 20 STATUS (TABLE) Table II of Phys.Rev.C97(2018)035806 O2446 2 21 HISTORY (20221224A) SD: Col.title in 5th field corrected O2446 2 22 (DATA -> ERR-T). O2446 2 23 ENDBIB 21 0 O2446 2 24 COMMON 3 3 O2446 2 25 ERR-1 ERR-2 ERR-3 O2446 2 26 PER-CENT PER-CENT PER-CENT O2446 2 27 10. 5. 3. O2446 2 28 ENDCOMMON 3 0 O2446 2 29 DATA 5 12 O2446 2 30 EN-CM DATA 1ERR-T 1DATA 2ERR-T 2 O2446 2 31 MEV MICRO-B MICRO-B B*MEV B*MEV O2446 2 32 1.681 30.9 3.6 9.04E+06 1.05E+06 O2446 2 33 1.879 120. 13. 9.68E+06 1.01E+06 O2446 2 34 1.978 170. 18. 7.75E+06 0.84E+06 O2446 2 35 2.177 415. 43. 6.82E+06 0.71E+06 O2446 2 36 2.276 619. 65. 6.44E+06 0.67E+06 O2446 2 37 2.376 920. 96. 6.25E+06 0.65E+06 O2446 2 38 2.475 1141. 119. 5.19E+06 0.54E+06 O2446 2 39 2.574 1683. 175. 5.25E+06 0.55E+06 O2446 2 40 2.673 2309. 240. 5.06E+06 0.53E+06 O2446 2 41 2.773 3026. 315. 4.74E+06 0.49E+06 O2446 2 42 2.872 4018. 421. 4.59E+06 0.48E+06 O2446 2 43 2.969 4614. 485. 3.94E+06 0.41E+06 O2446 2 44 ENDDATA 14 0 O2446 2 45 ENDSUBENT 44 0 O2446 299999 SUBENT O2446003 20190514 O070O2446 3 1 BIB 9 22 O2446 3 2 REACTION 1(34-SE-80(P,G)35-BR-81,,SIG) O2446 3 3 2(34-SE-80(P,G)35-BR-81,,SIG,,SFC) O2446 3 4 FACILITY (DYNAM,2GERTHS) 4-MV single-ended Dynamitron. O2446 3 5 DETECTOR (HPGE) Four hyper-pure Ge(HPGe) detectors. The relativeO2446 3 6 efficiency was almost 100 % for the three of them and O2446 3 7 76% for the fourth one. The Compton background O2446 3 8 suppressed by using four BGO crystals surrounding the O2446 3 9 Ge detectors. O2446 3 10 SAMPLE Two samples with areal densities of 106 +- 11 and O2446 3 11 132 +-13 ug/cm2. O2446 3 12 (34-SE-80,ENR=0.978) O2446 3 13 PART-DET (G) O2446 3 14 METHOD (BCINT) O2446 3 15 ANALYSIS (INTAD) Gamma-singles spectra measured at eight O2446 3 16 angles with respect to the beam direction. O2446 3 17 ERR-ANALYS (ERR-T) Total uncertainty calculated from the error O2446 3 18 propagation of: O2446 3 19 (ERR-1) thickness of the target - 10% O2446 3 20 (ERR-2) detector efficiency - 5% O2446 3 21 (ERR-3) accumulated charge - 3% O2446 3 22 (ERR-4,3.,30.) total angle-integrated yield. O2446 3 23 STATUS (TABLE) Table II of Phys.Rev.C97(2018)035806 O2446 3 24 ENDBIB 22 0 O2446 3 25 COMMON 3 3 O2446 3 26 ERR-1 ERR-2 ERR-3 O2446 3 27 PER-CENT PER-CENT PER-CENT O2446 3 28 10. 5. 3. O2446 3 29 ENDCOMMON 3 0 O2446 3 30 DATA 5 18 O2446 3 31 EN-CM DATA 1ERR-T 1DATA 2ERR-T 2 O2446 3 32 MEV MICRO-B MICRO-B B*MEV B*MEV O2446 3 33 1.482 8.53 1.03 1.19E+07 1.4E+06 O2446 3 34 1.681 37.4 4.0 1.10E+07 1.2E+06 O2446 3 35 1.782 75.0 8.2 1.11E+07 1.2E+06 O2446 3 36 1.880 133. 15. 1.07E+07 1.2E+06 O2446 3 37 1.981 242. 26. 1.09E+07 1.2E+06 O2446 3 38 2.078 389. 43. 1.04E+07 1.1E+06 O2446 3 39 2.180 611. 66. 9.94E+06 1.07E+06 O2446 3 40 2.277 881. 97. 9.16E+06 1.00E+06 O2446 3 41 2.379 1229. 137. 8.26E+06 9.2E+05 O2446 3 42 2.476 1726. 191. 7.84E+06 8.7E+05 O2446 3 43 2.577 2148. 237. 6.65E+06 7.3E+05 O2446 3 44 2.627 3006. 329. 7.77E+06 8.5E+05 O2446 3 45 2.677 2285. 254. 4.96E+06 5.5E+05 O2446 3 46 2.777 1492. 177. 2.32E+06 2.7E+05 O2446 3 47 2.876 1335. 156. 1.51E+06 1.8E+05 O2446 3 48 3.076 698. 95. 4.40E+05 6.0E+04 O2446 3 49 3.274 624. 96. 2.32E+05 3.6E+04 O2446 3 50 3.473 777. 112. 1.79E+05 2.6E+04 O2446 3 51 ENDDATA 20 0 O2446 3 52 ENDSUBENT 51 0 O2446 399999 SUBENT O2446004 20190514 O070O2446 4 1 BIB 8 20 O2446 4 2 REACTION 1(34-SE-74(P,G)35-BR-75,,SIG) O2446 4 3 2(34-SE-74(P,G)35-BR-75,,SIG,,SFC) O2446 4 4 FACILITY (VDGT,2GRCATH) 5.5-MV T11/25 Van de Graaff Tandem O2446 4 5 Accelerator Laboratory of NCSR "Demokritos" O2446 4 6 DETECTOR (HPGE) Sample-to-detector distance 15 cm. O2446 4 7 METHOD (ACTIV) Irradiation time: 4 h. O2446 4 8 End of irr. - start of measurement time: 6 to 15 min. O2446 4 9 (GSPEC) O2446 4 10 DECAY-DATA (35-BR-75,96.7MIN,DG,286.5,0.88) O2446 4 11 SAMPLE natSe samples with diameter of 20 mm and thickness of O2446 4 12 0.3 mm produced by evaporating metallic Se onto Al or O2446 4 13 Si wafers. O2446 4 14 ERR-ANALYS (ERR-T) Total uncertainty calculated from the error O2446 4 15 propagation of: O2446 4 16 (ERR-1) thickness of the target - 5% O2446 4 17 (ERR-2) detector efficiency - 3% O2446 4 18 (ERR-3) total beam charge - 3% O2446 4 19 (ERR-4,1.,12.) intensity of the gamma-transitions O2446 4 20 - statistical uncertainties. O2446 4 21 STATUS (TABLE) Table IV of Phys.Rev.C97(2018)035806 O2446 4 22 ENDBIB 20 0 O2446 4 23 COMMON 3 3 O2446 4 24 ERR-1 ERR-2 ERR-3 O2446 4 25 PER-CENT PER-CENT PER-CENT O2446 4 26 5. 3. 3. O2446 4 27 ENDCOMMON 3 0 O2446 4 28 DATA 5 9 O2446 4 29 EN-CM DATA 1ERR-T 1DATA 2ERR-T 2 O2446 4 30 MEV MICRO-B MICRO-B B*MEV B*MEV O2446 4 31 1.952 85.3 9.8 4.46E+06 5.1E+05 O2446 4 32 2.451 463. 51. 2.29E+06 2.5E+05 O2446 4 33 2.945 1203. 131. 1.05E+06 1.1E+05 O2446 4 34 3.438 2209. 240. 5.46E+05 5.9E+04 O2446 4 35 3.933 3804. 411. 3.32E+05 3.6E+04 O2446 4 36 4.426 4276. 468. 1.59E+05 1.7E+04 O2446 4 37 4.922 6585. 719. 1.19E+05 1.3E+04 O2446 4 38 5.416 7980. 870. 7.78E+04 0.86E+04 O2446 4 39 5.911 9042. 1009. 5.20E+04 0.58E+04 O2446 4 40 ENDDATA 11 0 O2446 4 41 ENDSUBENT 40 0 O2446 499999 SUBENT O2446005 20190514 O070O2446 5 1 BIB 8 21 O2446 5 2 REACTION 1(34-SE-80(P,N)35-BR-80,,SIG) O2446 5 3 2(34-SE-80(P,N)35-BR-80,,SIG,,SFC) O2446 5 4 FACILITY (VDGT,2GRCATH) 5.5-MV T11/25 Van de Graaff Tandem O2446 5 5 Accelerator Laboratory of NCSR "Demokritos" O2446 5 6 DETECTOR (HPGE) Sample-to-detector distance 15 cm. O2446 5 7 METHOD (ACTIV) Irradiation time: 4 h. O2446 5 8 End of irr. - start of measurement time: 6 to 15 min. O2446 5 9 (GSPEC) O2446 5 10 DECAY-DATA (35-BR-80-G,17.68MIN,DG,665.8,0.0108, O2446 5 11 DG,616.3,0.067) O2446 5 12 SAMPLE natSe samples with diameter of 20 mm and thickness of O2446 5 13 0.3 mm produced by evaporating metallic Se onto Al or O2446 5 14 Si wafers. O2446 5 15 ERR-ANALYS (ERR-T) Total uncertainty calculated from the error O2446 5 16 propagation of: O2446 5 17 (ERR-1) thickness of the target - 5% O2446 5 18 (ERR-2) detector efficiency - 3% O2446 5 19 (ERR-3) total beam charge - 3% O2446 5 20 (ERR-4,1.,12.) intensity of the gamma-transitions O2446 5 21 - statistical uncertainties. O2446 5 22 STATUS (TABLE) Table IV of Phys.Rev.C97(2018)035806 O2446 5 23 ENDBIB 21 0 O2446 5 24 COMMON 3 3 O2446 5 25 ERR-1 ERR-2 ERR-3 O2446 5 26 PER-CENT PER-CENT PER-CENT O2446 5 27 5. 3. 3. O2446 5 28 ENDCOMMON 3 0 O2446 5 29 DATA 5 7 O2446 5 30 EN-CM DATA 1ERR-T 1DATA 2ERR-T 2 O2446 5 31 MEV MB MB B*MEV B*MEV O2446 5 32 2.948 5.06 0.75 4.61E+06 6.6E+05 O2446 5 33 3.442 18.8 2.2 4.66E+06 5.3E+05 O2446 5 34 3.937 51.5 5.9 4.50E+06 5.1E+05 O2446 5 35 4.430 71.3 8.2 2.66E+06 3.0E+05 O2446 5 36 4.927 252. 29. 4.58E+06 5.1E+05 O2446 5 37 5.421 398. 45. 3.93E+06 4.4E+05 O2446 5 38 5.917 266. 30. 1.54E+06 1.7E+05 O2446 5 39 ENDDATA 9 0 O2446 5 40 ENDSUBENT 39 0 O2446 599999 SUBENT O2446006 20190514 O070O2446 6 1 BIB 8 27 O2446 6 2 REACTION 1(34-SE-82(P,N)35-BR-82,,SIG) O2446 6 3 2(34-SE-82(P,N)35-BR-82,,SIG,,SFC) O2446 6 4 FACILITY (VDGT,2GRCATH) 5.5-MV T11/25 Van de Graaff Tandem O2446 6 5 Accelerator Laboratory of NCSR "Demokritos" O2446 6 6 DETECTOR (HPGE) Sample-to-detector distance 15 cm. O2446 6 7 METHOD (ACTIV) Irradiation time: 4 h. O2446 6 8 End of irr. - start of measurement time: 6 to 15 min. O2446 6 9 (GSPEC) O2446 6 10 DECAY-DATA (35-BR-82-G,35.282HR,DG,554.3,0.711, O2446 6 11 DG,619.1,0.435, O2446 6 12 DG,698.4,0.283, O2446 6 13 DG,776.5,0.834, O2446 6 14 DG,827.8,0.240, O2446 6 15 DG,1044.0,0.283, O2446 6 16 DG,1317.5,0.268, O2446 6 17 DG,1474.9,0.1660) O2446 6 18 SAMPLE natSe samples with diameter of 20 mm and thickness of O2446 6 19 0.3 mm produced by evaporating metallic Se onto Al or O2446 6 20 Si wafers. O2446 6 21 ERR-ANALYS (ERR-T) Total uncertainty calculated from the error O2446 6 22 propagation of: O2446 6 23 (ERR-1) thickness of the target - 5% O2446 6 24 (ERR-2) detector efficiency - 3% O2446 6 25 (ERR-3) total beam charge - 3% O2446 6 26 (ERR-4,1.,12.) intensity of the gamma-transitions O2446 6 27 - statistical uncertainties. O2446 6 28 STATUS (TABLE) Table IV of Phys.Rev.C97(2018)035806 O2446 6 29 ENDBIB 27 0 O2446 6 30 COMMON 3 3 O2446 6 31 ERR-1 ERR-2 ERR-3 O2446 6 32 PER-CENT PER-CENT PER-CENT O2446 6 33 5. 3. 3. O2446 6 34 ENDCOMMON 3 0 O2446 6 35 DATA 5 9 O2446 6 36 EN-CM DATA 1ERR-T 1DATA 2ERR-T 2 O2446 6 37 MEV MB MB B*MEV B*MEV O2446 6 38 1.954 0.147 0.014 7.69E+06 7.3E+05 O2446 6 39 2.455 1.21 0.11 5.98E+06 5.5E+05 O2446 6 40 2.949 5.28 0.48 4.81E+06 4.4E+05 O2446 6 41 3.443 16.1 1.5 3.99E+06 3.6E+05 O2446 6 42 3.939 41.2 3.8 3.60E+06 3.3E+05 O2446 6 43 4.431 67.1 6.1 2.51E+06 2.3E+05 O2446 6 44 4.929 147. 13. 2.67E+06 2.4E+05 O2446 6 45 5.423 204. 19. 2.01E+06 1.8E+05 O2446 6 46 5.919 306. 28. 1.78E+06 1.6E+05 O2446 6 47 ENDDATA 11 0 O2446 6 48 ENDSUBENT 47 0 O2446 699999 SUBENT O2446007 20190514 O070O2446 7 1 BIB 8 25 O2446 7 2 REACTION (34-SE-0(P,X)35-BR-77,,SIG) O2446 7 3 Sotirios Charisopoulos (2019-10-07): The text in the O2446 7 4 8th page of the article "the weighted sum of the total O2446 7 5 cross sections of the 76Se(p,g)77Br and 77Se(p,n)77Br" O2446 7 6 explains the derivation of the cross section from TALYSO2446 7 7 (not from experiment). O2446 7 8 FACILITY (VDGT,2GRCATH) 5.5-MV T11/25 Van de Graaff Tandem O2446 7 9 Accelerator Laboratory of NCSR "Demokritos" O2446 7 10 DETECTOR (HPGE) Sample-to-detector distance 15 cm. O2446 7 11 METHOD (ACTIV) Irradiation time: 4 h. O2446 7 12 End of irr. - start of measurement time: 6 to 15 min. O2446 7 13 (GSPEC) O2446 7 14 DECAY-DATA (35-BR-77-G,57.04HR,DG,239.0,0.231, O2446 7 15 DG,520.7,0.224) O2446 7 16 SAMPLE natSe samples with diameter of 20 mm and thickness of O2446 7 17 0.3 mm produced by evaporating metallic Se onto Al or O2446 7 18 Si wafers. O2446 7 19 ERR-ANALYS (ERR-T) Total uncertainty calculated from the error O2446 7 20 propagation of: O2446 7 21 (ERR-1) thickness of the target - 5% O2446 7 22 (ERR-2) detector efficiency - 3% O2446 7 23 (ERR-3) total beam charge - 3% O2446 7 24 (ERR-4,1.,12.) intensity of the gamma-transitions O2446 7 25 - statistical uncertainties. O2446 7 26 STATUS (TABLE) Table IV of Phys.Rev.C97(2018)035806 O2446 7 27 ENDBIB 25 0 O2446 7 28 COMMON 3 3 O2446 7 29 ERR-1 ERR-2 ERR-3 O2446 7 30 PER-CENT PER-CENT PER-CENT O2446 7 31 5. 3. 3. O2446 7 32 ENDCOMMON 3 0 O2446 7 33 DATA 3 9 O2446 7 34 EN DATA ERR-T O2446 7 35 MEV MB MB O2446 7 36 1.978 0.168 0.020 O2446 7 37 2.485 0.898 0.086 O2446 7 38 2.985 3.15 0.30 O2446 7 39 3.485 9.57 0.90 O2446 7 40 3.987 24.6 2.3 O2446 7 41 4.486 32.1 3.0 O2446 7 42 4.989 59.3 5.6 O2446 7 43 5.490 86.7 8.1 O2446 7 44 5.991 108. 10. O2446 7 45 ENDDATA 11 0 O2446 7 46 ENDSUBENT 45 0 O2446 799999 SUBENT O2446008 20190514 O070O2446 8 1 BIB 7 14 O2446 8 2 REACTION (34-SE-78(P,G)35-BR-79-M/T,,SIG/RAT) O2446 8 3 FACILITY (DYNAM,2GERTHS) 4-MV single-ended Dynamitron. O2446 8 4 DETECTOR (HPGE) Four hyper-pure Ge(HPGe) detectors. The relativeO2446 8 5 efficiency was almost 100 % for the three of them and O2446 8 6 76% for the fourth one. The Compton background O2446 8 7 suppressed by using four BGO crystals surrounding the O2446 8 8 Ge detectors. O2446 8 9 SAMPLE The effective areal density 90 +- 9 ug/cm2 O2446 8 10 (34-SE-78,ENR=0.978) O2446 8 11 DECAY-DATA (35-BR-79-M,4.86SEC,DG,207.6) O2446 8 12 ERR-ANALYS (DATA-ERR) No information on sources of uncertainties. O2446 8 13 STATUS (UNOBT) Request for numerical datasent on 22 May 2019 O2446 8 14 to corresponding author O2446 8 15 (CURVE) Fig. 15 (a) of Phys.Rev.C97(2018)035806 O2446 8 16 ENDBIB 14 0 O2446 8 17 NOCOMMON 0 0 O2446 8 18 DATA 3 7 O2446 8 19 EN-CM DATA DATA-ERR O2446 8 20 MEV NO-DIM NO-DIM O2446 8 21 2.4 0.069 0.009 O2446 8 22 2.5 0.071 0.009 O2446 8 23 2.6 0.064 0.008 O2446 8 24 2.7 0.068 0.007 O2446 8 25 2.8 0.068 0.008 O2446 8 26 2.9 0.070 0.007 O2446 8 27 3.0 0.085 0.010 O2446 8 28 ENDDATA 9 0 O2446 8 29 ENDSUBENT 28 0 O2446 899999 SUBENT O2446009 20190514 O070O2446 9 1 BIB 7 15 O2446 9 2 REACTION (34-SE-80(P,G)35-BR-81-L/T,,SIG/RAT) O2446 9 3 FACILITY (DYNAM,2GERTHS) 4-MV single-ended Dynamitron. O2446 9 4 DETECTOR (HPGE) Four hyper-pure Ge(HPGe) detectors. The relativeO2446 9 5 efficiency was almost 100 % for the three of them and O2446 9 6 76% for the fourth one. The Compton background O2446 9 7 suppressed by using four BGO crystals surrounding the O2446 9 8 Ge detectors. O2446 9 9 SAMPLE natSe samples with diameter of 20 mm and thickness of O2446 9 10 0.3 mm produced by evaporating metallic Se onto Al or O2446 9 11 Si wafers. O2446 9 12 DECAY-DATA (35-BR-81-L,34.66MICROSEC,DG,260.2) O2446 9 13 ERR-ANALYS (DATA-ERR) No information on sources of uncertainties. O2446 9 14 STATUS (UNOBT) Request for numerical datasent on 22 May 2019 O2446 9 15 to corresponding author O2446 9 16 (CURVE) Fig. 15 (b) of Phys.Rev.C97(2018)035806 O2446 9 17 ENDBIB 15 0 O2446 9 18 NOCOMMON 0 0 O2446 9 19 DATA 3 16 O2446 9 20 EN-CM DATA DATA-ERR O2446 9 21 MEV NO-DIM NO-DIM O2446 9 22 1.7 0.039 0.006 O2446 9 23 1.8 0.026 0.003 O2446 9 24 1.9 0.036 0.004 O2446 9 25 1.9 0.029 0.003 O2446 9 26 2.0 0.029 0.004 O2446 9 27 2.1 0.030 0.003 O2446 9 28 2.2 0.027 0.003 O2446 9 29 2.3 0.037 0.005 O2446 9 30 2.3 0.038 0.004 O2446 9 31 2.4 0.035 0.004 O2446 9 32 2.5 0.032 0.003 O2446 9 33 2.5 0.040 0.005 O2446 9 34 2.6 0.039 0.005 O2446 9 35 2.7 0.045 0.005 O2446 9 36 2.8 0.043 0.006 O2446 9 37 3.0 0.038 0.006 O2446 9 38 ENDDATA 18 0 O2446 9 39 ENDSUBENT 38 0 O2446 999999 ENDENTRY 9 0 O244699999999