ENTRY T0012 20181008 C179T0012 0 1 SUBENT T0012001 20181008 C179T0012 1 1 BIB 9 19 T0012 1 2 INSTITUTE (1CANUBC) T0012 1 3 REFERENCE (J,CJP,34,381,1956) T0012 1 4 AUTHOR (G.B.Chadwick,T.F.Alexander,J.B.Warren) T0012 1 5 TITLE Gamma radiation from the proton bombardment of boron T0012 1 6 ten T0012 1 7 SAMPLE Targets were of magnetically separated 10B, stated to T0012 1 8 be 400 mu-g/cm2 and 250 mu-g/cm2 thick, deposited on T0012 1 9 gold and platinum. T0012 1 10 FACILITY (VDG,1CANUBC) T0012 1 11 DETECTOR (NAICR) Sodium-iodide scintillation counter consisting T0012 1 12 of a 2 in. long by 1.75 in. diam. sodium iodide block T0012 1 13 mounted on an R.C.A. 6342 photomultiplier. T0012 1 14 MONITOR Gamma energies determined by calibrating the system T0012 1 15 with 2.62-MeV gamma from Th and 6.13-MeV gamma T0012 1 16 from the reaction 19F(p,a+g)16O. T0012 1 17 Occasional further calibrations made with the 9.17-MeV T0012 1 18 gamma ray from 13C(p,gamma). T0012 1 19 HISTORY (19990414C) SD/VM T0012 1 20 (20181004A) OS. REACTION code in sub.5 modified T0012 1 21 ENDBIB 19 0 T0012 1 22 NOCOMMON 0 0 T0012 1 23 ENDSUBENT 22 0 T0012 199999 SUBENT T0012002 20181008 C179T0012 2 1 BIB 3 4 T0012 2 2 REACTION (5-B-10(P,A)4-BE-7,PAR,SIG) T0012 2 3 ERR-ANALYS (DATA-ERR) Total error. T0012 2 4 STATUS (TABLE) Data taken from text of reference. T0012 2 5 Data given in Fig.5 for Ep 0.5 to 2.0 MeV. T0012 2 6 ENDBIB 4 0 T0012 2 7 NOCOMMON 0 0 T0012 2 8 DATA 4 1 T0012 2 9 EN E-LVL DATA DATA-ERR T0012 2 10 MEV MEV B B T0012 2 11 1.53 0.43 0.21 0.05 T0012 2 12 ENDDATA 3 0 T0012 2 13 ENDSUBENT 12 0 T0012 299999 SUBENT T0012003 20000412 0000T001200300001 BIB 2 3 T001200300002 REACTION (5-B-10(P,G)6-C-11,PAR,SIG) T001200300003 STATUS Data given in Fig.2 for 9 MeV gamma at Ep 0.5 to 2.0 T001200300004 MeV. T001200300005 ENDBIB 3 0 T001200300006 NOCOMMON 0 0 T001200300007 NODATA 0 0 T001200300008 ENDSUBENT 7 0 T001200399999 SUBENT T0012004 20181008 C179T0012 4 1 BIB 3 4 T0012 4 2 REACTION (5-B-10(P,G)6-C-11,PAR,DA,,RS0) T0012 4 3 ERR-ANALYS (DATA-ERR) No information on source of uncertainty. T0012 4 4 STATUS (TABLE) Data taken from text in reference. T0012 4 5 Data given in Fig.3 for 9 MeV gamma at Ep 1.2 MeV. T0012 4 6 ENDBIB 4 0 T0012 4 7 COMMON 2 3 T0012 4 8 EN E T0012 4 9 MEV MEV T0012 4 10 1.2 9. T0012 4 11 ENDCOMMON 3 0 T0012 4 12 DATA 3 1 T0012 4 13 ANG DATA DATA-ERR T0012 4 14 ADEG NO-DIM NO-DIM T0012 4 15 90. 1.5 0.05 T0012 4 16 ENDDATA 3 0 T0012 4 17 ENDSUBENT 16 0 T0012 499999 SUBENT T0012005 20181008 C179T0012 5 1 BIB 4 9 T0012 5 2 REACTION 1(5-B-10(P,G),,WID) T0012 5 3 2(5-B-10(P,G)6-C-11,,SIG,,RES) T0012 5 4 ERR-ANALYS1(DATA-ERR) No information on source of estimated T0012 5 5 uncertainty. T0012 5 6 2(DATA-ERR) Main contributions to estimated uncertainty T0012 5 7 in peak cross section are from counter efficiency and T0012 5 8 target thickness. T0012 5 9 STATUS (TABLE) Data taken from text of reference. T0012 5 10 HISTORY (20181004A) SF4 added to REACTION 2 T0012 5 11 ENDBIB 9 0 T0012 5 12 NOCOMMON 0 0 T0012 5 13 DATA 6 1 T0012 5 14 EN-RES EN-RES-ERR DATA 1DATA-ERR 1DATA 2DATA-ERR 2T0012 5 15 KEV KEV KEV KEV MICRO-B MICRO-B T0012 5 16 1135. 15. 540. 40. 3.5 1. T0012 5 17 ENDDATA 3 0 T0012 5 18 ENDSUBENT 17 0 T0012 599999 ENDENTRY 5 0 T001299999999