IAEA Coordinated Research Project for
Development of a Database for Prompt Gamma-Ray Neutron Activation Analysis

Data for Te Isotopes (Z=52)

IsotopeAbundanceSigma(old) Sigma(new)Data Intensity Balances Energy Fit
120Te0.09 1%2000 300 mb (to 0)
ReferencesComments: 340 60 mb (to 294.0)
122Te2.55 12%3900 500 mb * 1190 90 mb ENSDFBudapest ENSDFBudapest ENSDFBudapest
ReferencesComments: 300 30 mb (to 247.5), 1100 500 mb (Mughabghab, to 247.5). * Updated (2003)
Final adopted data , Intensity balance , Energy/Intensity Fit
123Te0.89 3%418 30 b 339 18 b ENSDFBudapest ENSDFBudapest ENSDFBudapest
ReferencesComments:
Final adopted data , Intensity balance , Energy/Intensity Fit
124Te4.74 14%6800 1300 mb 7730 250 mb ENSDFBudapest ENSDFBudapest ENSDFBudapest
ReferencesComments: 770 70 mb (to 144.8) 40 25 mb (Mughabghab, to 144.8)
Final adopted data , Intensity balance , Energy/Intensity Fit
125Te7.07 15%1550 160 mb 700 70 b Budapest Budapest Budapest
ReferencesComments:
Final adopted data , Intensity balance
126Te18.84 25%900 150 mb (to 0) 28 7 mb (to 0) Budapest Budapest Budapest
ReferencesComments: 135 23 mb (to 88.3)
Final adopted data , Intensity balance
128Te31.74 8%200 8 mb (to 0) 157 10 mb (to 0) ENSDFBudapest ENSDFBudapest ENSDFBudapest
ReferencesComments: 29.0 22 mb (to 105.5), 15 1 mb(Mughabghab to 105.5), 194 2 mb (De Corte, to 0)
Final adopted data , Intensity balance , Energy/Intensity Fit
130Te34.08 62%270 6 mb (to 0) 132 10 mb (to 0) ENSDFBudapest ENSDFBudapest ENSDFBudapest
ReferencesComments: 20 10 mb (Mughabghab, to 182.2), 194 2 mb (De Corte, to 0)
B- Decay (25.0 m) 54 6 mb, needs correction for bombardment time.
Final adopted data , Intensity balance

Comparison of ENSDF and Budapest Gamma-Ray Data

Final Comparison of Adopted Data, Budapest, and Lone.

Return

For more information contact

Richard B. Firestone, e-mail: rbf@lbl.gov
Ernest O. Lawrence Berkeley National Laboratory
MailStop 88R0192
1 Cyclotron Road
Berkeley, CA 94720
Phone: 510-486-7646
Fax: 510-486-5757