Detailed information about experiment is presented in Annals of Atomic Energy
Short discription of the data base:
- Source of primary neutron: accelerator based reaction T(p,n) in polyethylene block
- Detector of delayed neutron spectra: He-3 spectrometer
- Time of sample irradiation: short irradiation (tir=20 s) and long irradiation (tir=120 s)
- Method of measurements: cyclic irradiation of sample and measurements of delayed neutron spectra in
time
windows (indicated in tables)
- Processing of the data (see the reference paper)
- The database can be used as a benchmark for validation of both delayed neutron spectra from
individual
precursors and for delayed neutron spectra for group data.
New: The determination of the uncertainties of the integral spectra is described in INDC(NDS)-0849.
The following sources of uncertainties were considered:
-
Statistical uncertainties - ΔNc
-
Neutron background uncertainties - ΔNb
-
Uncertainties of the spectrum of recoil nuclei 3He - ΔNHe-3 and recoil protons - ΔNp, as
well as the uncertainties of thermal peak - ΔNτ
- Uncertainties of the efficiency of the neutron spectrometer - ΔNeff and the attenuation
function
of the neutron flux in the lead filter - ΔNPb.