Selenium (Z=34)
70Se 73Se 74Se 75Se 76Se 77Se 78Se 79Se 80Se 82Se

Recommended magnetic dipole moments
Isotope Energy [keV] t1/2 Spin/Parity μ [nm] Method Recommended Tables
74Se 635 7.08 ps 2+ +0.74(11) TF INDC(NDS)-0816
1269 4.0 ps 2+ 1.0(2) TF INDC(NDS)-0816
1363 1.86 ps 4+ 1.7(3) TF INDC(NDS)-0816


Recommended electric quadrupole moments
Isotope Energy [keV] t1/2 Spin/Parity Q [b] Method Recommended Tables
74Se 635 7.08 ps 2+ -0.36(7) CER INDC(NDS)-0833


Compiled magnetic dipole and electric quadrupole moments from published articles
Isotope Energy [keV] t1/2 Spin/Parity μ [nm] Q [b] Ref. Std Method NSR keyword doi
74Se 635. 7.08 ps 2+ +0.86(5) [82Se 654.] TF 1998SP03 10.1103/PhysRevC.57.2181
-0.36(7) CER 1978LE22
2013STZZ
10.1103/PhysRevC.18.2801
1269. 4.0 ps 2+ 1.1(2) [82Se 654.] TF 1998SP03 10.1103/PhysRevC.57.2181
1363. 1.86 ps 4+ 2.0(4) [82Se 654.] TF 1998SP03 10.1103/PhysRevC.57.2181

Recommended magnetic moments are for the bare nucleus with published results corrected consistently for diamagnetism (including error estimate).
  Where appropriate published results are also adjusted to the most recent adopted half-life for the state.
  Recommended quadrupole moments are adjusted using the best electric field gradient calculation for the system concerned.
  For details see the Reports referenced.

In this listing published results are given without adjustment or correction.